The website is currently under maintenance and certain documents are yet to be uploaded.

Earthing Failure in LT Distribution: What Degrades Between Tests

An earthing system can pass this year’s test and still be worse than it was last year. The reading is correct. What one reading cannot show is the direction. Quick answer Earthing in LT distribution degrades between tests through four causes: electrode corrosion, seasonal change in soil resistivity, loose or oxidised joints, and nearby civil […]

Distribution Transformer Monitoring: The Four Signals Scheduled Rounds Miss

A transformer can pass its 11 am round and still run above its rating every evening until the next one. The reading was accurate. It just was not the reading that mattered. Quick answer Distribution transformer monitoring tracks four conditions that scheduled rounds see only as single readings: time above rating, phase imbalance drift, leakage […]

How to Read an RDSS Tender: What It Funds, What It Doesn’t, and Where the Risk Sits

Quick answer An RDSS tender funds smart metering, network strengthening, and sometimes the LT layer between the distribution transformer and the consumer — but central assistance is results-linked, released only when the utility meets reform benchmarks, not simply when equipment is delivered. Read the tender for three things: what the scheme funds, what the utility […]

Technical vs Commercial Loss Explained — With a Feeder-Level Test

Quick answer Diagram of a distribution transformer energy  Technical loss is energy lost as heat in conductors and transformers. Commercial loss is energy delivered but never billed, or billed and never paid. Many energy accounts arrive at technical loss as a leftover, so it absorbs every estimating error. An energy balance at each distribution transformer […]

FRP vs Metal Electrical Enclosures: How to Compare the Real 25-Year Cost

Quick Answer There is no universally better material for an outdoor electrical enclosure. For relatively dry, low-corrosion environments, properly designed and coated steel can offer excellent performance at a lower initial cost. As corrosion exposure increases — particularly in coastal, humid or aggressive industrial environments — SMC/FRP can become increasingly attractive because the enclosure body […]

Electrical Safety in LT Distribution: The Hidden Risks

More than 12,000 people die from electrocution in India every year — around 30 every single day, according to National Crime Records Bureau data. Most of these deaths don’t happen at high-voltage substations behind locked gates. They happen at the low-tension (LT) edge of the grid: the poles, boxes and service lines that sit closest […]

Why DISCOMs Need Intelligent LT Distribution Systems

A DISCOM Chief Engineer with 2,000+ feeders told me last month: “We have smart meters telling us consumption is down 5%, but our AT&C loss number didn’t move. That’s not possible unless the 5% is being lost somewhere between the transformer and the consumer meter.” He was right. And he was looking at the wrong […]

How RDSS Is Transforming India’s Power Distribution Infrastructure

RDSS Phase 2: why smart LT distribution is now critical to delivery A state-level RDSS implementation officer told me: “We’ve met our smart meter target, we’ve deployed the DMS, we’ve got visibility into consumption. But AT&C losses barely moved. The data showed us the problem exists — it didn’t help us solve it.” That gap […]

What Is Pulse Box and Why India Needs Smart LT Distribution

A DISCOM Chief Engineer asked me last month:“If RDSS smart meters are giving us all this data, why are our fault rates still where they were?” It’s a fair question. India has spent the better part of a decade and ₹3.03 lakh crore under the Revamped Distribution Sector Scheme building a measurement layer for the […]

Fill the form to download the catalogue

Reducing Electrical Loss in Maharashtra's High-Density Zones

Problem:

  • Energy meters were situated in deeply recessed, poorly lit areas,making access and reading challenging.
  • Rampant meter tampering incidents were reported. Even when detected, intimidation and threats prevented whistleblowing.
  • Regions like Kalyan, close to Mumbai, witnessed up to 53% power loss primarily due to illicit power theft.

Innovative Solution: 

Introduction of RMC’s Multi Meter Boxes: These units encapsulate 12 meters in a single structure, complicating consumer efforts to single out their individual meters.

  •  By eliminating easy access points, these boxes ensure protection against tampering attempts.

  • Strategically relocating these boxes to main roads achieves dual objectives: simplifying meter reading tasks and reducing tampering. Their public positioning acts as a deterrent, making tampering attempts risky and less likely.

RMC Switchgears Ltd is a Jaipur-based company manufacturing smart energy enclosures, panels, and electrical safety solutions.